Simple Simplex®

Simple Simplex®
Literature
SSP-1
SSP-2
SSP-3

Overview:

The Simple Simplex® Control Panels will alert of a high liquid level and are designed to control a single phase pump. Applications include sewage pump chambers, sump pump basins, lift stations, and onsite installations. The controls are housed in an 8”x 6”x 4” NEMA 4X indoor/outdoor polycarbonate enclosure and UL listed in the United States and Canada.

Simple Simplex® 1:

The Simple Simplex® 1 will alert of a high liquid level and control a 120/208/240V single phase pump. Models are available in 2 or 3 float operation.

  • NEMA 4X enclosure with lockable latch
  • Red beacon LED alarm light
  • Alarm horn sounds at 85 decibels at 10’
  • Alarm test and silence buttons with automatic reset
  • Pump control relay - 16FLA rating
  • Alarm fuse

Models:

  • SSP-1 = 2 float operation
  • SSP-1-3 = 3 float operation

Simple Simplex® 2:

The Simple Simplex® 2 will alert of a high liquid level and control a 120/208/240 single phase pump. The system includes an (HOA) Hand-Off-Auto toggle switch, green pump light, and high liquid alarm dry contacts. Models are available in 2 or 3 float operation.

Features:

  • NEMA 4X enclosure with lockable latch
  • Red beacon LED alarm light
  • Alarm horn sounds at 85 decibels at 10’
  • Alarm test and silence buttons with automatic reset
  • (H.O.A.) Hand-Off-Auto toggle switch and green pump run light
  • Pump control relay - 16FLA rating
  • Alarm fuse
  • High liquid alarm dry contacts

Models:

  • SSP-2 = 2 float operation
  • SSP-2-3 = 3 float operation

Simple Simplex® 3:

The Simple Simplex® 3 plugger control panel will alert of a high liquid level and includes a 120V receptacle for quick and easy installation of the pump/pump switch.

Features:

  • NEMA 4X enclosure with lockable latch
  • Red beacon LED alarm light
  • Alarm horn sounds at 85 decibels at 10’
  • Alarm test and silence buttons with automatic reset
  • 120V receptacle for pump/pump switch
  • Pump control relay - 16FLA rating
  • High liquid alarm dry contacts
  • Alarm fuse

Models:

  • SSP-2 = 2 float operation
  • SSP-2-3 = 3 float operation

Custom Options

  • S3 = No floats included
  • HH = High high level alarm
  • LL = Low level alarm
  • BB = 9V battery backup for alarm circuit
  • AF = Alarm flasher
  • C = Additional cord length greater than 20’ Specify after C.
    Example: (SSP-1-C50) indicates 50’ cord lengths for all components
  • PA-KIT = Pedestal assembly post junction box kit
  • 95-28 = Mechanically activated wide angle float switch, controls pumps up to 1/2 HP at 120V
Get in Touch: 888-733-9283